ReadyPlanet.com
dot dot


SAREL by Schneider Electric
Phoenix Contact
Cablofil Cable tray system
VIPA


System 500 V.

 

 VIPA System 500S - Accessoires

Article
Description
953-1LG00
MCC - Memory extansion card 128kByte
for SPEED7-CPUs, 64kByte program/64kByte data
 
953-1LK00
MCC - Memory extansion card 1MByte
for SPEED7-CPUs, 512kByte program/512kByte data
 
953-1LH00
MCC - Memory extansion card 256kByte
for SPEED7-CPUs, 128kByte program/128kByte data
 
953-1LL00
MCC - Memory extansion card 2MByte
for SPEED7-CPUs, 1MByte program/1MByte data
 
953-1LE00
MCC - Memory extansion card 32kByt
for SPEED7-CPUs, 16kByte program/16kByte data
 
953-1LM00
MCC - Memory extansion card 4MByte
for SPEED7-CPUs, 2MByte program/2MByte data
 
953-1LJ00
MCC - Memory extansion card 512kByte
for SPEED7-CPUs, 256kByte program/256kByte data
 
953-1LF00
MCC - Memory extansion card 64kByte
for SPEED7-CPUs, 32kByte program/32kByte data
 
953-1LP00
MCC - Memory extansion card 8MByte
for SPEED7-CPUs, 4MByte program/4MByte data
 

System 500S

The PC control system
With the VIPA "Speed7 Technology", system 500S is the fastest control system, programmable with Step®7 from Siemens, in the world. The maximum memory for program and data has already been integrated into the SPEED7 CPUs. Depending on the CPU type, the integrated memory can be expanded up to 8MByte respectively using the appropriate VIPA MCC - Memory extansion card.

The VIPA system 500S has been designed for operation in a PC slot with PCI interface. An OPC server for communication between CPU and PC is included in the scope of delivery. Peripherals are connected through the integrated Profibus-DP-Master interface.

The CPUs are equipped with an Ethernet interface for PG/OP communication. The CPU 517S/NET has an additional CP343 for TCP/IP communication. Owing to their high performance (Speed7 Technology) and their scaleable memory, the CPUs are suitable for complex control tasks.

Features of VIPA System 500S:

  • Programmable with WinPLC7 from VIPA
  • Programmable with Step®7 from Siemens
  • Integrated work memory - operation is possible without additional memory card!
  • Flexible extension of the memory using a Memory Configuration Card (MCC) for the desired upgrade
  • Integrated battery backed RAM memory
  • Real-time clockSupports standard MMC cards for saving of programme and data
  • Ethernet-, Profibus-DP and MPI interface on board
  • OPC server included
  • 24 months warranty
  • UL-standard certification

 

ystem 500S - CPUs

CPUs-Central Modules

System 500S CPU SPEED7 represents a full PLC CPU in the form of a PCI bus card for PC-based applications. Windows operating systems 98, ME, NT4, 2000 and XP are supported.

The scope of performance corresponds to that of a SPEED7 CPU from System 300S. Programming is done using the standard programming tools WinPLC7 or Siemens STEP7.

For the connection to the process level, an MPI and a PROFIBUS-DP master interface are available. In addition, depending on the CPU type, a CP 543 for communication tasks is integrated. The scope of supply includes the OPC Server.

After the hardware installation, the plug-in card from the PC is connected as "Intel Ethernet integrated interface". To operate the card independent from of the PC, it will be supplied externally with DC 24 V.

In the CPUs of System 500S memory for code and data is already integrated. It can be expanded by inserting a MCC memory card into the MMC slot. To back up program and data standard MMC cards are also supported.

Due to the high performance and scalable memory, the CPUs of System 500S are especially suitable for complex control tasks.

Operation Safety
- External power supply for the CPU (autarchic operation)
- ESD / Burst 61000-4-2/IEC in accordance with IEC 61000-4-4 (up to level 3)
- Shock resistance in accordance with IEC 60068-2-6 / IEC 60068-2-27 (1G/12G)
 

Order no.
Name/Description
515-2AJ00
CPU 515S/DPM - SPEED7 technology
external DC 24V power supply, 1MByte work memory expandable up to 2MByte (50% program/50% data), MP²I, MMC slot, real-time clock␍
Interface:
Profibus-DP master, 12Mbit/s, up to 124 slaves, PCI-Ethernet interface for PU/OP communication, incl. SW110A2LA OPC server␍(SW110A2LA please order separately)
 
517-2AJ00
CPU 517S/DPM - SPEED7 technology
external DC 24V power supply, 2MByte work memory expandable up to 8MByte (50% program/50% data), MP²I, MMC slot, real-time clock␍
Interface:
Profibus-DP master, 12Mbit/s, up to 124 slaves, PCI-Ethernet interface for PU/OP communication, incl. SW110A2LA OPC server␍(SW110A2LA please order separately)
 
517-4NE00
CPU 517S/NET - SPEED7 technology
external DC 24V power supply, 2MByte work memory expandable up to 8MByte (50% program/50% data), MP²I, MMC slot, real-time clock␍
Interface:
Profibus-DP master, 12Mbit/s, up to 124 slaves, PCI-Ethernet interface for PU/OP communication, incl. SW110A2LA OPC server (SW110A2LA please order separately), 2nd slot: Ethernet-CP 543, S7 communication, RFC1006, H1, TCP/IP, UDP, up to 16 connections
 




VIPA

System SLIO
System 100 V.
System 200 V.
System 300 V.
System HMI
Software
Accessories



Copyright © 2010 All Rights Reserved.
EXINTECH AUTOMATION CO.,LTD. Tel : +66-2130-5839 Fax : +66-2130-5840 Email : sales@exintech.co.th Line ID : pandami3